1. DIN 5510-2 fire test to railway components – wire or cable- Standard Title: DIN 5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
2. DIN 5510-2 fire test to railway components – wire or cable - Standard Introduction: DIN 5510-2 determinate the fire classification of railway vehicle material and structure by burning behaviour, smoke density and dropping behavieour.
3. DIN 5510-2 fire test to railway components – wire or cable - Products Scope: DIN 5510-2 is acceptable to all train, railway vehicle, metro defined in EBO, ESBO, BOStrab
4. DIN 5510-2 fire test to railway components – wire or cable - Test Method:
>> Material and component of railway vehicle - Cable Test method: > DIN EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C
> DIN EN 61034-2 Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus
Smoke toxic test according new version DIN 5510-2:2009:05, DIN EN ISO 5659-2, Smoke toxic test (toxicity measured with FTIR)
5. DIN 5510-2 fire test to railway components – wire or cable – Reference Standard:
> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C
> DIN EN 50266-2-5 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-5: procedures – Category D
> DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods
> DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
> DIN EN 60332-2-2 Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame;
> DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus.
> DIN EN ISO 5659-2: Smoke generation -- Part 2: Determination of optical density by a single-chamber test
|