Codes and Standards‎ > ‎Industry‎ > ‎Wire & Cable‎ > ‎

DIN 5510-2


Fire Testing for Railway Components – Wire or Cable – DIN 5510-2

 


 

 

1.       DIN 5510-2 fire test to railway components – wire or cable- Standard Title

DIN 5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.

 

2.       DIN 5510-2 fire test to railway components – wire or cable - Standard Introduction

DIN 5510-2 determinate the fire classification of railway vehicle material and structure by burning behaviour, smoke density and dropping behavieour.

 

3.       DIN 5510-2 fire test to railway components – wire or cable - Products Scope

DIN 5510-2 is acceptable to all train, railway vehicle, metro defined in EBO, ESBO, BOStrab

 

4.       DIN 5510-2 fire test to railway components – wire or cable - Test Method

   

>> Material and component of railway vehicle - Cable

Test method

DIN EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame

 

> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C

 

DIN EN 61034-2 Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus

 

Smoke toxic test according new version DIN 5510-2:2009:05, DIN EN ISO 5659-2, Smoke toxic test (toxicity measured with FTIR)

 

 

5.       DIN 5510-2 fire test to railway components – wire or cable – Reference Standard:

 

> DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C

 

> DIN EN 50266-2-5 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-5: procedures – Category D

 

> DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods

 

> DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame

 

> DIN EN 60332-2-2 Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame;

 

> DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus.

 

> DIN EN ISO 5659-2: Smoke generation -- Part 2: Determination of optical density by a single-chamber test